Showing posts with label Plastic. Show all posts
Showing posts with label Plastic. Show all posts

Tuesday, February 18, 2014

DIY Venturi~ " A Few Easy Builds for Aquaponics, Aquaculture, or Hydroponics"


Published on Nov 1, 2013

I really like the idea of aerating the fish tank by venturi to save some coin & help make the system quieter.. A mate shared an idea with me for a unit he had been working on & was happy with...

I decided to have a crack at his idea along with a few others to see which I thought would work the best for our set up...

I was most pleased with the results & ended up going with the "Bear Unit".. I have had one in the aquaponic fish tank for over 2 weeks now with no issues & have plans to add another to a moving bed bio filter that will be added to the system soon...

Was also very pleased with the off the shelf unit purchased from Earthan group.. That one will be going into the moving bed bio filter in the recirculating aquaculture system..

Below are a couple of pages I found helpful when looking into venturis,

http://www.youtube.com/watch?v=Wokswr...
http://en.wikipedia.org/wiki/Venturi_...
http://leisure.prior-it.co.uk/venturi...

Below is an explanation of "Fine bubble aeration" along with some useful links/references,
http://en.wikipedia.org/wiki/Water_ae...

Hope this is of help to some out there...
For more regular updates from the chooks, worms, aquaponic & wicking gardens come visit us at http://www.facebook.com/Bitsouttheback

Have a great one all...



The Venturi effect is the reduction in fluid pressure that results when a fluid flows through a constricted section of pipe. The Venturi effect is named after Giovanni Battista Venturi (1746–1822), an Italian physicist.



The pressure in the first measuring tube (1) is higher than at the second (2), and the fluid speed at "1" is lower than at "2", because the cross-sectional area at "1" is greater than at "2".

Background

The Venturi effect is a jet effect; as with a funnel the velocity of the fluid increases as the cross sectional area decreases, with the static pressure correspondingly decreasing. 

According to the laws governing fluid dynamics, a fluid's velocity must increase as it passes through a constriction to satisfy the principle of continuity, while its pressure must decrease to satisfy the principle of conservation of mechanical energy. 

Thus any gain in kinetic energy a fluid may accrue due to its increased velocity through a constriction is negated by a drop in pressure.

When a fluid such as water flows through a tube that narrows to a smaller diameter, the partial restriction causes a higher pressure at the inlet than that at the narrow end. 

This pressure difference causes the fluid to accelerate toward the low pressure narrow section, in which it thus maintains a higher speed. 

The Venturi meter uses the direct relationship between pressure difference and fluid speeds to determine the volumetric flow rate.



A flow of air through a venturi meter, showing the columns connected in a U-shape (a manometer) and partially filled with water. The meter is "read" as a differential pressure head in cm or inches of water.

Relationship between pressure and flow speed

An equation for the drop in pressure due to the Venturi effect may be derived from a combination of Bernoulli's principle and the continuity equation.

Referring to the diagram to the right, using Bernoulli's equation in the special case of incompressible flows (such as the flow of water or other liquid, or low speed flow of gas), the theoretical pressure drop at the constriction is given by:
p_1 - p_2 = \frac{\rho}{2}\left(v_2^2 - v_1^2\right)
where \scriptstyle \rho\, is the density of the fluid, \scriptstyle v_1 is the (slower) fluid velocity where the pipe is wider, \scriptstyle v_2 is the (faster) fluid velocity where the pipe is narrower (as seen in the figure). This assumes the flowing fluid (or other substance) is not significantly compressible - even though pressure varies, the density is assumed to remain approximately constant.

Choked flow

The limiting case of the Venturi effect is when a fluid reaches the state of choked flow, where the fluid velocity approaches the local speed of sound. 

 In choked flow the mass flow rate will not increase with a further decrease in the downstream pressure environment. 

However, mass flow rate for a compressible fluid can increase with increased upstream pressure, which will increase the density of the fluid through the constriction (though the velocity will remain constant). 

This is the principle of operation of a de Laval nozzle. Increasing source temperature will also increase the local sonic velocity, thus allowing for increased mass flow rate.



Flow in a Venturi tube

 

 

Source: Wikipedia.org


Somebody Come and Play Today! Earn as You Learn, Grow as You Go!

The Man Inside the Man
from
Sinbad the Sailor Man
A
JMK's Production


Share this page





TTFN
CYA Later Taters!
Thanks for stopping by.

Donnie/Sinbad the Sailor Man

P.S. Sweet Sixteen My Breakout Year's Hottest and Fastest Growing Biz Op? Do You Want In? If You Do! Click Here and Sign Up!

Saturday, November 16, 2013

The Aquaponics Garden is Put Up for the Winter

Hey All, Donnie/ Sinbad the Sailor Man.

Just stopping by to let ya know what is up with the Aquaponics Greenhouse.

Well I cleaned it up and straightened It out some. I still want to put a new layer of wood chips up in the Greenhouse before I quit for the winter.

Plus I would love to rebuild the sump pit box and get a lid on It, back fill and landscape It some before the snow starts to fall or the ground freezes solid.

I took some pictures of It as it sits on the 15th of November 2013




I moved all the tanks to one end and mowed the weeds down. Picked up all of the cut offs and PVC scraps and put them in and behind the East end flower box.

I flipped the troughs over to keep rain water and ice out. I emptied the large tanks and rotated the large fish tank to keep water out as well.

I will flip this little Pond liner here in this picture and put it in the Greenhouse upside down until spring.

If we get funding we will do our best to get things put together before Spring if we get a warm enough day or two to work especially with plastic sheeting. It tends to tear when too cold.


This is the North side of the Aquaponics Greenhouse. The height of the 1,200 gallon tank when It is sitting on the dirt box is just under ten feet.

The Green house is seven and a half foot tall at Its highest point. There are fourteen different style tanks, three six foot round by 18 inch deep kiddie pools, two one hundred gallon troughs, and two fifty gallon troughs; as well as 90 foot of 4 inch PVC pipe.


The whole Garden area will sit upon a 20 x 60 foot section of this backyard. When the Aquaponics Green house is fully operational it will hold over 3,000 gallons of water that is less than one tanker load of water that we use to drill an average 75 foot deep water Well.

She is not design to raise fish but to operate on them. As little as about five hundred adult fish. Will supply this garden with enough nutrients for an average four acre soil garden. 112 feet of flood and drain covered inside a Green house and 480 running feet of raised soil beds outside of the green house.

Not including the Seven pocket Towers we will crowd into and out of the systems Green house areas.
 

This is the West end of the Greenhouse looking towards the East so far she has a small foot print as everything is compacted together. When complete their will be another 30 x 12 by ten foot tall Greenhouse directly in line and behind this one.

Which will hold our flood and drain troughs. Between these two Green houses will be a covered Breeze way that will enclose the large section tanks.

This Greenhouse has cost so far about two hundred dollars. When sheeted I am guessing it will be close to four hundred and when fully enclosed about five hundred fifty dollars.

That is for a Green house that is 30 foot long by 12 foot wide by 7 1/2 foot tall. This was purposely built this low for heat conservation.


Here you can get a good look at the size of those new raised bed planters that I picked up from a customer of the Well Service. After I get the Garden cycling I plan to build a dozen or so more of this size Planter boxes.


Here you can see some black Polly scraps both one inch and two inch tubing. And if you look behind the planter you see a pile of four inch PVC pipe.


This is the East side looking towards the West. I will be laying down some more wood chips as soon as the ground stiffens up or freezes some.

From the edge of the Greenhouse back another forty feet towards the East. Plus I'll drop a load or two off for the inside of the Greenhouse itself.


This is a four foot deep by 4 x 8 foot box made from treated plywood CDX and some old 4 x 4's


That was a complete walk around the Green house plus I was showing you all that the Sump pit is empty again but they are calling for rain so whats a guy gonna do?

TTFN
CYA Later Taters
Thanks for stopping by.

Donnie/ Sinbad the Sailor Man